-
Brun Erickson posted an update 20 hours, 15 minutes ago
We further showed by co-immunoprecipitation that Rac1 interacts with SRSF2, hnRNPA1, and U2A’ in response to EGF. The interaction is dependent on T108 phosphorylation and facilitated by Rac1 PBR and GTPase activity. We showed that hnRNPA1 translocated in and out of nucleus in response to EGF in a similar pattern to Rac1. Rac1 only partially colocalized with U2A’ that localizes to the actual splicing sites adjacent to nuclear speckle. Finally, we showed that Rac1 regulated EGF-induced pre-mRNA splicing and this is mediated by T108 phosphorylation. We conclude that in response to EGF, T108 phosphorylated Rac1 is targeted to nuclear speckles, interacts with multiple groups of proteins involved in pre-mRNA splicing, and regulates EGF-induced pre-mRNA splicing.
In this analysis of the EWOLUTION registry, we evaluated the incidence, relevance and predictors of device-related thrombus in a large multi-center real-world cohort undergoing LAAc with the WATCHMAN device.
We analyzed the 835 patients who underwent percutaneous LAA closure with the WATCHMAN device in the EWOLUTION registry in whom at least one TEE follow up was performed. Patients were 74 ± 9 y/o and were at high risk for stroke and bleeding (CHA2DS2-VASC-Score 4.3 ± 1.7; HAS-BLED-Score 2.3 ± 1.2). Device-related thrombus was detected in 4.1% (34/835) after a median of 54 days (IQR 42-111 days) with 91.2% (31/34) being detected within 3 months after the procedure or at the time of first TEE. Hereby DRT occurred irrespective of postprocedural anticoagulation. Patients with DRT more frequently had long-standing, non-paroxysmal atrial fibrillation (82.4 vs. 64.9%, p < .01), evidence of dense spontaneous echo contrast (26.5 vs. 11.9%, p = .03) and larger LAA diameters at the ostium (22.8 ± 3.5 vs. 21.1 ±n most cases.
In real-world patients undergoing LAAc with the WATCHMAN device, DRT is rare. DRT was most frequently detected within the first 3 months after LAAc regardless of post-procedural regimen and was not associated with an increased risk of stroke or SE. While long-standing atrial fibrillation was the only independent factor associated with DRT, medical treatment of DRT resulted in a resolution of thrombi in most cases.Cervical cancer is the most common gynaecological malignancy, with a high incidence rate and mortality rate in middle-aged women. Human bone marrow mesenchymal stem cells (hBMSCs) have been implicated in the initiation and subsequent development of cancer, along with the involvement of extracellular vesicles (EVs) mediating intracellular communication by delivering microRNAs (miRNAs or miRs). This study is aimed at investigating the physiological mechanisms by which EVs-encapsulated miR-144-3p derived from hBMSCs might mediate the progression of cervical cancer. The expression profiles of centrosomal protein, 55 Kd (CEP55) and miR-144-3p in cervical cancer cell lines and tissues, were quantified by RT-qPCR and Western blot analysis. CORT125134 manufacturer The binding affinity between miR-144-3p and CEP55 was identified using in silico analysis and luciferase activity determination. Cervical cancer cells were co-cultured with EVs derived from hBMSCs that were treated with either miR-144-3p mimic or miR-144-3p inhibitor. Cervical cancer cell proliferation, invasion, migration and apoptosis were detected in vitro. The effects of hBMSCs-miR-144-3p on tumour growth were also investigated in vivo. miR-144-3p was down-regulated, whereas CEP55 was up-regulated in cervical cancer cell lines and tissues. CEP55 was targeted by miR-144-3p, which suppressed cervical cancer cell proliferation, invasion and migration and promoted apoptosis via CEP55. Furthermore, similar results were obtained by hBMSCs-derived EVs carrying miR-144-3p. In vivo assays confirmed the tumour-suppressive effects of miR-144-3p in hBMSCs-derived EVs on cervical cancer. Collectively, hBMSCs-derived EVs-loaded miR-144-3p impedes the development and progression of cervical cancer through target inhibition of CEP55, therefore providing us with a potential therapeutic target for treating cervical cancer.
The unprecedented COVID-19 pandemic has put a serious burden on the healthcare system worldwide. Due to varied manifestations of SARS-CoV-2 infection, many scoring systems, which were earlier used for community acquired pneumonia (CAP) are in use to determine the disease severity and the need of ICU admissions for proper management. COVID-19 is a relatively new disease and the validity of these scoring systems in SARS-CoV-2 infection is not completely known. This study aimed to validate these scoring systems in cases of COVID-19 pneumonia in an Indian setup. The study has also tried to find the most accurate indicator of disease severity and 14-day mortality among these scoring systems.
This study included 122 SARS-CoV-2 infected patients at a tertiary hospital in Ranchi, Jharkhand. The severity of the disease according to ICMR protocol for COVID-19, the PSI/PORT score, the CURB-65 score and the SCAP score were calculated in all the patients and analysed with the disease outcome, that is, 14-day mortality.
SCAP score, PSI/PORT score and CURB-65 criteria, all were good indicators of disease severity and 14-day mortality. However, when compared to other scoring systems, SCAP score was a more accurate marker of disease severity and 14-day mortality.
The PSI/PORT scoring system, the CURB-65 criteria and the SCAP scoring system can be used to assess the COVID-19 severity and predict the 14-day mortality risk in cases of COVID-19 pneumonia.
The PSI/PORT scoring system, the CURB-65 criteria and the SCAP scoring system can be used to assess the COVID-19 severity and predict the 14-day mortality risk in cases of COVID-19 pneumonia.
This randomized clinical trial aimed to compare the outcomes of the mandibular overdenture retained by one (1-IOD) or two (2-IOD) implants.
Participants received new complete dentures, were assessed at baseline and randomly assigned to groups. Early loaded single midline implant (1-IOD) or two implants in the canine regions bilaterally (2-IOD). Ball attachments were used for overdenture retention. Post-treatment outcomes (6- and 12-month follow-ups) included patient satisfaction, oral health-related quality of life measures, and chewing function. Data analysis included within- and between-group comparisons, and Generalized Estimating Equations. Both superiority and non-inferiority hypotheses were tested.
Forty-seven participants were included (1-IOD=23; 2-IOD=24). Significant improvements in OHIP-Edent were observed after insertion of new dentures and at the 1-year follow-up compared with baseline. No differences were found between the 1- and 2-IOD groups for the OHIP-Edent and QoLFAST scores. Patient satisfaction with the mandibular denture improved significantly from baseline to the 6-month follow-up and remained unaltered until 1year, with no differences between groups.